CDR, MW, rep 2

Cedar Wood

Description

This experiment is on a system consisting of a Cedar Wood cladding panel and a Mineral Wool (MW) insulation panel, separated with a cavity of 50 mm width. It is the second repetition of this system configuration.

Experiment Notes

The front facing camera experienced failure at the beggining of the experiment, however returned at 23 minutes.

Test Details
Cladding Cedar Wood
Cladding Thickness [mm] 12
Insulation Mineral Wool (MW)
Insulation thickness [mm] 100
Cavity width [mm] 50
Repetition number 2
Metrics
Peak HRR [kW] 107
Time to Peak HRR [mins] 3.52
Total HR [MJ] 34.7
Peak dQ/dt [kW/s] 1.12
Time to Peak dQ/dt [mins] 3.62
Residual HRR [kW] 2.18
Test Pictures (click to zoom)
Download Data (CSV) Download Data (PDF)
Video
HRR [kW] including burner baseline
Minutes
30